Core processor CPU with 400M main frequency, it can complete the complex run quickly and realize intelligent defect analysis. Low power design with large capacity and high performance lithium ion battery module,it can work more than 10 hours continuously. Full English master-slave menu, emphasizing on user experience, collecting shortcut keys, digital shuttle rotary wheel, cross menu three operating way in one body, customer with different habits can operate it freely. It supports many languages. Its waterproof, oil proof, dustproof function can achieve IP65 protection level. It is the necessary professional precision instrument for defect detection, quality control, on-line safety monitoring and life evaluation in fields of oil, chemical, metallurgy, shipbuilding, aviation, railways and so on.
The instrument can be widely used in locating and sizing hidden cracks, voids, disbands and similar discontinuities in welds, forgings, billets, axles, shafts, tanks, pressure vessels, turbines and structural components.
Measuring Range |
(0 ~ 9999) mm at steevelocity |
Bandwidth |
0.2 to 20MHz automatic matching according to the probe frequency |
MateriaVelocity |
(300 ~ 15000) m / s |
Dynamic Range |
≥ 36dB |
VerticaLinear Error |
≤ 2.5% |
HorizontaLinear Error |
≤ 0.1% |
Resolution |
> 40dB (5P14) |
Sensitivity Leavings |
65dB (flat-bottomed deep hole 200mmФ2) |
Rejection |
(0 to 80)% Linear without affecting the linearity and gain |
Noise Leve |
≤ 8% |
Probe Type |
straight beam probe, angle beam probe, duaelement probe, through-transmit probe |
Gates |
Wave-getting Gate, Wave-losing Gate, Single Gate Reading, DuaGate Reading; both peak and edge can |
Alarm |
Beep Alarm and LED light Alarm |
Power Supply |
DC 9V |
Working Time |
>10 hours |
OveralDimensions |
280 × 220 × 70(mm) |
Operating Temperature |
(-10 ~ 50) ℃ |
Relative Humidity |
(20 ~ 95)% RH |
Pulse Energy |
200V, 300V, 400V, 500V, 600V selectable, suitable for various probe |
Pulse Width |
(0.1~0.512)µs range with continuous adjustment to match the different frequency probes |
Probe Damping |
68Ω、100Ω、150Ω、500Ωselectable to meet different requirements for resolution and sensitivity. |
Sampling |
10 digits AD Converter at the sampling speed of 160MHz, waveform of highly fidelity. |
Rectification |
Positive half wave, negative half wave, fulwave, RF |
Gate Reading |
optionafor single gate and double gate reading mode, both peak and edge can trigger it |
Gain |
0 dB to 110 dB adjustable in selectable steps 0.1 dB, 1 dB, 2dB and 6dB |
Probe Connections |
BNC or LEMO |